1.General Introduction
ABB TSP311 temperature transmitter is a heavy duty modular type sensor without thermowell which used for insertion in an existing or separate thermowell, sensor can be replaced during operation, transmitter head can be either integrated or remote mounted, both RTD and thermocouple sensors accepted, sensor meets SIL2 approval when integrated with transmitter. Both TTH200 and TTH300 can be integrated; recommend using an LC display with type AS display function if using a TTH200 and LCD indicator with type A if using TTH300.
2.Compare Table of TSP311 TPS321 and TSP311
Type | TSP311 | TSP321 | TSP331 |
Design | No thermowell, for installation in existing thermowell | Welded protective fitting manufactured from pipe material | Drilled thermowell manufactured from bar stock material |
Measuring inset, extension tube with thermowell interface, connection head, transmitter, optional LCD display | |||
Process connection | Insertion in an existing thermowell.
| Screw-in thread, flange, compression fitting | Welded connections, screw-in thread, flange |
Transport temperature / Storage temperature | -20 to 70℃ (-4 to 158°F) | ||
Maximum temperature limits | (depending on the sensor and material selected, the lower temperature value in each case counts) | ||
Sensor | Thin film resistor: 400℃(752°F), wire wound resistor: 800℃ (1472°F), Thermocouples type K, N, J, E, L, S: 1600℃ (2912°F) | ||
Material | Temperature limits | ||
316L / 1.4404 | ≤ 800℃ (1472°F) | ||
316Ti / 1.4571 | ≤ 800℃ (1472°F) | ||
Inconel 600 / 2.4816 | ≤ 1100℃ (2012°F) | ||
Hastelloy C276 / 2.4819 | — | ≤ 1100℃ (2012°F) | ≤ 1100℃ (2012°F) |
Monel 400 / 2.4360 | — | — | 600℃ (1112°F) |
1.7335 | — | — | ≤ 540℃ (1004°F) |
1.7380 | — | — | ≤ 570℃ (1058°F) |
1.5415 | — | — | ≤ 500℃ (932°F) |
E-CTFE | — | ≤ 120℃ (248°F) | ≤ 120℃ (248°F) |
Tantalum | — | ≤ 250℃ (482°F) | ≤ 250℃ (482°F) |
Pressure | Maximum 40 ... 100 bar (580.15 bar ... 1450.38 psi) | Maximum 700 bar (10152.64 psi) |
3.Basic Code Selection of TSP311 Temperature Transmitter
Main Code | Suffix Codes | Description | |||||||||
TSP311 | SensyTemp TSP311 Temperature Sensor, without thermowell, for heavy duty applications | ||||||||||
Explosion Protection / Approvals | Y0 | Without explosion protection | |||||||||
A1 | Intrinsic Safety ATEX II 1 G Ex ia IIC T6 Ga or II 2 G Ex ib IIC T6 Gb or II 1/2 G Ex ib IIC T6 Ga/Gb | ||||||||||
A3 | Dust ignition proof ATEX II 1 D IP6x | ||||||||||
A4 | Dust ignition proof ATEX II 1 D IP6x T133 ... T400 and Intrinsic Safety ATEX II 1 G Ex ia IIC T6 ... T1 | ||||||||||
A5 | Flameproof enclosure ATEX II 1/2 G Ex d IIC T1 - T6 Ga/Gb | ||||||||||
B1 | Non incentive ATEX II 3 G Ex nA IIC T1 - T6 Gc and ATEX II 3 D Ex tc IIIB T133°C Dc | ||||||||||
B5 | Dust ignition proof ATEX II 1 D IP6x T133 and Flameproof enclosure ATEX II 1/2 G Ex d IIC T6 | ||||||||||
H1 | Intrinsic Safety IECEx ia IIC T6 Ga | ||||||||||
H2 | Intrinsic Safety IECEx ib IIC T6 Gb or IECEx ib IIC T6 Ga/Gb | ||||||||||
H5 | Flameproof enclosure IECEx d IIC T1 - T6 Ga/Gb | ||||||||||
N1 | Intrinsic Safety acc. NAMUR NE 24 and ATEX II 1 G Ex ia IIC T6 Ga | ||||||||||
G1 | GOST Russia - metrological approval | ||||||||||
P2 | GOST Russia - metrological approval and EAC-Ex, Ex i - Zone 0 | ||||||||||
P3 | GOST Russia - metrological approval and EAC-Ex, Ex d | ||||||||||
P4 | GOST Russia - metrological approval and EAC-Ex, dust ignition proof | ||||||||||
G3 | GOST Kazakhstan - metrological approval | ||||||||||
T2 | GOST Kazakhstan - metrological approval and EAC-Ex, Ex i - Zone 0 | ||||||||||
T3 | GOST Kazakhstan - metrological approval and EAC-Ex, Ex d | ||||||||||
T4 | GOST Kazakhstan - metrological approval and EAC-Ex, dust ignition proof | ||||||||||
M5 | GOST Belarus - metrological approval | ||||||||||
U2 | GOST Belarus - metrological approval and EAC-Ex, Ex i - Zone 0 | ||||||||||
U3 | GOST Belarus - metrological approval and EAC-Ex, Ex d | ||||||||||
U4 | GOST Belarus - metrological approval and EAC-Ex, dust ignition proof | ||||||||||
Extension Tube Length | Y0 | Without Extension Tube | |||||||||
K1 | K = 150 mm (6 inch) | ||||||||||
Z9 | Customer specific length | ||||||||||
Thermowell Connection | W1 | No extension / Connection head with thread M24x 1.5 | |||||||||
W2 | No extension / Connection head with thread 1/2 inch NPT | ||||||||||
W3 | No extension / Connection head with lock nut M24x 1.5 | ||||||||||
W4 | Double nipple / G 1/2 A / G 1/2 A | ||||||||||
W5 | Double nipple / 1/2 in. NPT / 1/2 in. NPT | ||||||||||
G1 | Extension tube with Cylindrical thread G 1/2 A | ||||||||||
G2 | Extension tube with Cylindrical thread G 3/4 A | ||||||||||
G3 | Extension tube with Cylindrical thread G 3/8 A | ||||||||||
M1 | Extension tube with Cylindrical thread M14x1.5 | ||||||||||
M2 | Extension tube with Cylindrical thread M18x1.5 | ||||||||||
M3 | Extension tube with Cylindrical thread M20x1.5 | ||||||||||
M4 | Extension tube with Cylindrical thread M24x1.5 | ||||||||||
M5 | Extension tube with Cylindrical thread M27x1.5 | ||||||||||
N1 | Extension tube with conical thread 1/2 in. NPT | ||||||||||
N2 | Nipple / 1/2 in. NPT / 1/2 in. NPT | ||||||||||
N3 | Nipple-Union / 1/2 in. NPT / Union 1/2 in. NPT | ||||||||||
N4 | Nipple - Union - Nipple / 1/2 in. NPT / 1/2 in. NPT | ||||||||||
U6 | Extension with Male nut, thread G 1/2 in. | ||||||||||
A1 | Extension tube with adjustable compression fitting G 1/2 A | ||||||||||
A2 | Extension tube with adjustable compression fitting 1/2 in. NPT | ||||||||||
Z9 | Others | ||||||||||
Immersion Length | U2 | U = 140 mm (5.6 in.) | |||||||||
U4 | U = 200 mm (8 in.) | ||||||||||
U6 | U = 260 mm (10.3 in.) | ||||||||||
Z9 | Customer specific length | ||||||||||
Measuring Inset Type | S1 | RTD, TF, Basic application, measuring range -50 ... 400℃ (-58 ... 752°F), 10 g | |||||||||
S2 | RTD, TF, Extended vibration resistance, measuring range -50 ... 400℃ (-58 ... 752°F), 60 g | ||||||||||
S3 | RTD, TF, Extended measuring range -196 ... 400℃ (-321 ... 752°F), 10 g | ||||||||||
S4 | RTD, TF, Extended vibration resistance, extended measuring range -196 ... 400℃ (-321 ... 752°F), 60 g | ||||||||||
D1 | RTD, WW, Extended measuring range -196 ... 600℃ (-321 ... 1112°F), 10 g | ||||||||||
D3 | RTD, WW, Extended vibration resistance, extended measuring range -196 ... 600℃ (-321 ... 1112°F), 60 g | ||||||||||
E1 | RTD, adjustable to German calibration regulations, sign of app. 000/308 - without calibration | ||||||||||
E2 | RTD, custody preliminary, adjustable to German regulations, - with calibration -10℃ and +50℃ | ||||||||||
T1 | Thermocouple | ||||||||||
Z9 | Others | ||||||||||
Measuring Inset Diameter | D3 | 3 mm | |||||||||
D4 | 4.5 mm | ||||||||||
D6 | 6 mm | ||||||||||
D8 | 8 mm | ||||||||||
H8 | 8 mm, tip with sleeve, DIN 43735 Sleeve 80 mm (RTD), 20 mm (TC) | ||||||||||
H1 | 10 mm, tip with sleeve 80 mm (RTD), 20 mm (TC) | ||||||||||
Z9 | Others | ||||||||||
Sensor Type and Wiring | P1 | 1 x Pt100, 2-wire | |||||||||
P2 | 1 x Pt100, 3-wire | ||||||||||
P3 | 1 x Pt100, 4-wire | ||||||||||
P4 | 2 x Pt100, 2-wire | ||||||||||
P5 | 2 x Pt100, 3-wire | ||||||||||
P6 | 2 x Pt100, 4-wire | ||||||||||
P8 | 1 x Pt1000, 2-wire | ||||||||||
P7 | 1 x Pt1000, 3-wire | ||||||||||
P9 | 1 x Pt1000, 4-wire | ||||||||||
K1 | 1 x Type K (NiCr-NiAl) | ||||||||||
K2 | 2 x Type K (NiCr-NiAl) | ||||||||||
K3 | 3 x Type K (NiCr-NiAl) | ||||||||||
J1 | 1 x Type J (Fe-CuNi) | ||||||||||
J2 | 2 x Type J (Fe-CuNi) | ||||||||||
L1 | 1 x Type L (Fe-CuNi) | ||||||||||
L2 | 2 x Type L (Fe-CuNi) | ||||||||||
N1 | 1 x Type N (NiCrSi-NiSi) | ||||||||||
N2 | 2 x Type N (NiCrSi-NiSi) | ||||||||||
T1 | 1 x Type T (Cu-CuNi) | ||||||||||
T2 | 2 x Type T (Cu-CuNi) | ||||||||||
E1 | 1 x Type E (NiCr-CuNi) | ||||||||||
E2 | 2 x Type E (NiCr-CuNi) | ||||||||||
S1 | 1 x Type S (Pt10Rh-Pt) | ||||||||||
S2 | 2 x Type S (Pt10Rh-Pt) | ||||||||||
Z9 | Others | ||||||||||
Sensor Accuracy | B2 | Accuracy Class B, IEC 60751 | |||||||||
D2 | Wire Wound, Double, Accuracy Class A, IEC 60751, Range 0 ... 250℃ (32 ... 482°F) | ||||||||||
D1 | Wire Wound, Accuracy Class A, IEC 60751, Range -100 ... 450℃ (-148 ... 842°F) | ||||||||||
S1 | Thin Film, Accuracy Class A, IEC 60751, Range -30 ... 300℃ (-22 ... 572°F) | ||||||||||
S3 | Thin Film, Accuracy Class AA, IEC 60751, Range 0 ... 100℃ (0 ... 212°F) | ||||||||||
S6 | Thin Film, Accuracy Class A extended according to IEC 60751, Range -196 ... 400℃ (-320,8 ... 752°F) | ||||||||||
S8 | Thin Film, Accuracy Class AA extended according to IEC 60751, Range -196 ... 400℃ (-320,8 ... 752°F) | ||||||||||
T2 | Thermocouple, Accuracy Class 2, IEC 60584 | ||||||||||
T1 | Thermocouple, Accuracy Class 1, IEC 60584 | ||||||||||
T4 | Thermocouple, Standard Accuracy ANSI MC96.1 | ||||||||||
T3 | Thermocouple, Special Accuracy ANSI MC96.1 | ||||||||||
T5 | Thermocouple, Accuracy according to DIN 43710 | ||||||||||
Z9 | Others | ||||||||||
Connection Head Type / Material | L1 | AGL / Aluminium, screwed cover | |||||||||
L2 | AGLH / Aluminium, high cover, screwed | ||||||||||
L4 | AGLD / Aluminium, screwed cover with display | ||||||||||
S1 | AGS / Stainless steel, screwed cover | ||||||||||
S2 | AGSH / Stainless steel, high cover, screwed | ||||||||||
S4 | AGSD / Stainless steel, screwed cover with display | ||||||||||
Z9 | Others | ||||||||||
Transmitter | Y1 | Without transmitter, sensor with ceramic terminal block - spring loaded | |||||||||
Y2 | Without transmitter, sensor with flying leads and metal plate - spring loaded | ||||||||||
H4 | TTH300-HART, programmable, output signal 4 ... 20mA, dual input | ||||||||||
H5 | TTH300-HART, Ex version, programmable, output signal 4 ... 20mA, dual input | ||||||||||
P6 | TTH300-PA, programmable, output PROFIBUS PA, dual input | ||||||||||
P7 | TTH300-PA, Ex version, programmable, output PROFIBUS PA, dual input | ||||||||||
F6 | TTH300-FF, programmable, output FOUNDATION fieldbus H1, dual input | ||||||||||
F7 | TTH300-FF, Ex version, programmable, output FOUNDATION fieldbus H1, dual input | ||||||||||
H6 | TTH200-HART, programmable, output signal 4 ... 20mA | ||||||||||
H7 | TTH200-HART, Ex version, programmable, output signal 4 ... 20mA | ||||||||||
Optional Codes | /Optional codes |
4.Installation for Normal Diameter and Small Diameters
Address: P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
Tel: +971558915937
Fax: +971558915956
E-mail:
info@rostockgroup.com
technical@rostockgroup.com
commercial@rostockgroup.com
Get the latest special offers and discount information sent to your email address.
Copyright © Rostock Group Co.,Limited All Rights Reserved. Sitemap