1. General Introduction
Rosemount 765 Multi-input Temperature sensor is integrated with water level sensor which also measure free water level at the bottom of the tank which enable correct measurement of volume. It is hung vertically from the top of the tank, and the position/length is chosen according to the actual bottom water range. 765 Multi-input Temperature sensor should be anchored to the tank bottom to ensure a fixed position in case of turbulence. One of the Pt-100 temperature sensor elements can be installed inside the water level probe allowing temperature measurements at low levels. The water level sensor delivers a digital signal, and is connected to the Rosemount 2240S Multi-input Temperature Transmitter.
2. Basic code selection of 765 Multi-input Temperature sensor
0765 | Multiple Spot Temperature Sensor with integrated water level sensor | |||||||||||
Overall length | Mxxxxx | Metric units, xxxxx in millimeters (mm). Range: 02000-60000 | ||||||||||
Exxxxx | U.S. units, xxxxx in inches (in.). Range: 00400-02300 | |||||||||||
Sheath type | A | 1-in. (25.4-mm) AISI 316 | ||||||||||
Tank connection | A | 1 1/2-in. Class 150 | ||||||||||
B | 1 1/2-in. Class 300 | |||||||||||
C | 2-in. Class 150 | |||||||||||
D | 2-in. Class 300 | |||||||||||
E | 3-in. Class 150 | |||||||||||
F | 3-in. Class 300 | |||||||||||
G | 4-in. Class 150 | |||||||||||
H | 4-in. Class 300 | |||||||||||
1 | DN 50 PN 16 | |||||||||||
2 | DN 50 PN 40 | |||||||||||
3 | DN 65 PN 16 | |||||||||||
4 | DN 65 PN 40 | |||||||||||
5 | DN 80 PN 16 | |||||||||||
6 | DN 80 PN 40 | |||||||||||
7 | DN 100 PN 16 | |||||||||||
Threaded connection | 0 | M33x1.5 | ||||||||||
Temperature sensor wiring | 4 | Four-wire (maximum10 spot elements) | ||||||||||
0 | No temperature sensor - water level sensor only | |||||||||||
Number of temperature spot elements | 01-10 | Specify number | ||||||||||
00 | No temperature sensor - water level sensor only | |||||||||||
Element type | P | Pt-100 | ||||||||||
0 | No temperature sensor - water level sensor only | |||||||||||
Temperature accuracy class | 1 | 1/6 DIN Class B (IEC/EN60751) | ||||||||||
0 | No temperature sensor - water level sensor only | |||||||||||
Temperature range | 1 | 0 to +120℃ (+32 to +248℉) | ||||||||||
Lead wires, temperature sensor | 00 | Integrated installation with Rosemount 2240S (standard) | ||||||||||
04-10 | Specify other length in meters | |||||||||||
13-33 | Specify other length in feet | |||||||||||
Water level sensor | C05 | Closed, suitable for light products, 500-mm | ||||||||||
C10 | Closed, suitable for light products, 1000-mm | |||||||||||
H05 | Open, suitable for crude and heavy duty products, 500-mm | |||||||||||
H10 | Open, suitable for crude and heavy duty products, 1000-mm | |||||||||||
Optional codes | Optional codes |
3. Typical mounting drawing for 765 Multi-input Temperature sensor
Address: P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
Tel: +971558915937
Fax: +971558915956
E-mail:
info@rostockgroup.com