1. General Introduction
Rosemount 2410 Tank Hub handles communication between the field devices and the control room. It calculates average temperature, observed density, and strapping table based volume and such data can be presented on the optional integrated back-lit display, a separate Rosemount 2230 Graphical Field Display, and can be sent to Rosemount TankMaster or a host system. The Rosemount 2410 also supports the auto-configuration of the Tankbus devices within the Rosemount Tank Gauging System which acts as a FOUNDATION Fieldbus master on the Tankbus, which means it identifies and auto-addresses field devices in the network, manages communication, and supervises the status of all connected devices. It also includes extensive built-in diagnostics. The device is available in two versions, for single and multiple tanks and provides IEC 61508 certified SIL 2
and SIL 3 overfill prevention alarm outputs for the Rosemount Tank Gauging System.
2. Basic code selection of Rosemount 2410 Tank Hub
2410 | Tank Hub | ||||||||||||||
Tankbus: number of tanks | S | Single tank | |||||||||||||
M | Multiple tanks (up to ten level devices per tank hub) | ||||||||||||||
Tankbus: Power and communication | F | Intrinsically safe FOUNDATION Fieldbus | |||||||||||||
Primary fieldbus | R | TRL2 Modbus | |||||||||||||
4 | RS485 Modbus | ||||||||||||||
E | Enraf Bi-phase Mark GPU | ||||||||||||||
B | Analog output 4-20mA/HART | ||||||||||||||
7 | Analog input 4-20mA/HART | ||||||||||||||
Secondary fieldbus | R | TRL2 Modbus | |||||||||||||
E | Enraf Bi-phase Mark GPU | ||||||||||||||
W | WirelessHART (IEC 62591) connectivity (IS) | ||||||||||||||
L | L&J Tankway Slave 1500 XL/MCG 2000 | ||||||||||||||
V | Varec Mark/Space GT 1800/1900 | ||||||||||||||
H | Whessoe WM 550/660 (digital current loop) | ||||||||||||||
G | GPE 31422/31423 (digital current loop) | ||||||||||||||
U | Sakura(MDP/V1) | ||||||||||||||
T | Tokyo Keiso | ||||||||||||||
C | Analog output 4-20mA/HART, active (IS) | ||||||||||||||
A | Analog output 4-20mA/HART, active (non-IS) | ||||||||||||||
D | Analog output 4-20mA/HART, passive (IS) | ||||||||||||||
B | Analog output 4-20mA/HART, passive (non-IS) | ||||||||||||||
8 | Analog input 4-20mA/HART, active (IS) | ||||||||||||||
6 | Analog input 4-20mA/HART, active (non-IS) | ||||||||||||||
9 | Analog input 4-20mA/HART, passive (IS) | ||||||||||||||
7 | Analog input 4-20mA/HART, passive (non-IS) | ||||||||||||||
0 | None | ||||||||||||||
F | None, ready for upgrade of secondary bus | ||||||||||||||
Safety certification (SIS) | 3 | Certified IEC 61508 SIL 3 | |||||||||||||
S | Certified IEC 61508 SIL 2 | ||||||||||||||
F | None, ready for upgrade of safety certification (SIS) | ||||||||||||||
0 | None | ||||||||||||||
Relay output | 2 | 2xSPST, solid-state | |||||||||||||
1 | 1xSPST, solid-state | ||||||||||||||
F | None, ready for upgrade of relay output | ||||||||||||||
0 | None | ||||||||||||||
Integral display | 1 | LCD | |||||||||||||
0 | None | ||||||||||||||
Power supply | P | Extended input range: 48-240 Vac at 50/60 Hz, and 24-48 Vdc | |||||||||||||
Firmware | S | Standard | |||||||||||||
Hazardous location certification | E1 | ATEX Flameproof | |||||||||||||
E7 | IECEx Flameproof | ||||||||||||||
E5 | FM-US Explosion-proof | ||||||||||||||
E6 | FM-Canada Explosion-proof | ||||||||||||||
E4 | Japan Flameproof | ||||||||||||||
E2 | INMETRO Flameproof (Brazil) | ||||||||||||||
NA | No hazardous location certification | ||||||||||||||
Custody transfer type approval | R | OIML R 85 edition 2008 | |||||||||||||
C | PTB Eich (Germany) | ||||||||||||||
K | GOST (Kazakhstan) | ||||||||||||||
L | LNE (France) | ||||||||||||||
N | NMi (The Netherlands) | ||||||||||||||
S | GOST (Russia) | ||||||||||||||
0 | None | ||||||||||||||
Housing | A | Aluminum (polyurethane-covered), IP 66/67 | |||||||||||||
Cable/conduit connections | 1 | ½-14 NPT and ¾-14 NPT | |||||||||||||
2 | M20 x 1.5 and M25 x 1.5 adapters | ||||||||||||||
G | Metal cable glands (1/2–14 NPT) | ||||||||||||||
E | Eurofast male connector | ||||||||||||||
M | Minifast male connector | ||||||||||||||
Mechanical installation | W | Wall installation kit included | |||||||||||||
P | Mounting kit for both wall and pipe installation | ||||||||||||||
Optional codes | Optional codes |
3. Typical application drawing of Rosemount 2410 Tank Hub
Address: P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
Tel: +971558915937
Fax: +971558915956
E-mail:
info@rostockgroup.com
technical@rostockgroup.com
commercial@rostockgroup.com
Get the latest special offers and discount information sent to your email address.
Copyright © Rostock Group Co.,Limited All Rights Reserved. Sitemap