1. General Introduction
Tokyo Keiso FS Spring Displacer Level Transmitter detects and indicates liquid level by spring balanced displacer. Along with local level indication by pointer dial, alarm contacts, pneumatic output or electric output can be provided for versatile application. Its features list as follows:
- Applicable for High temp and High press.(vacuum)
- Beside normal liquid level measurement, two liquid interface and liquid density measurement is possible
- Wide variation of material selection for corrosive liquids
2. Short Specifications
Model | FS | |
Measuring theory | Spring Balanced, Displacement | |
Measuring object | Liquid (Viscosity: Max. 600 mPa·s. Liquid without sticking, crystallization, or freezing) Level measurement: Standard range 0.7 to 1.3 g/cm³ Interface measurement: Density difference Min. 0.2g/cm³ *Other density range available on request. However, size of connection flanges may differ from standard sizes. | |
Measuring range | Min. 0 to 300mm Max. 0 to 3000mm | |
Temperature range | Std.: -10 to +150ºC Low temp. version: -40 to -11ºC With radiation fin High temp. version: +151 to +350ºC With radiation fin | |
Pressure range | Low press. version: Max. 1MPa Medium press. Version: Max. 2MPa High press. version: Contact us for details | |
Material construction | Spring: SUS316, UNS N10276, others Displacer: SUS304, SUS316, SUS316L, others Upper flange: Carbon steel, SUS304, SUS316, SUS316L, others Chamber: Carbon steel, SUS304, SUS316, SUS316L, others | |
Process connection | Tank top without chamber Measuring range up to 1000mm: 4B flange Measuring range more than 1000mm: 3B flange
Tank top bolt-on internal chamber Measuring range up to 1000mm: 5B flange Measuring range more than 1000mm: 4B flange
Tank side external chamber:1-1/2B flange | |
Indication accuracy | ±1.5% F.S. (Based on mass conversion correction at factory calibration) | |
Output | 4 With alarm contact: Max. 6 point(SPDT), Set point accuracy: ±1%F.S. With electric transmitter: DC 4 - 20mA, Output accuracy: ±1%F.S. With pneumatic transmitter: 20 - 100kPa, Output accuracy: ±1%F.S. | |
Construction | W: Weather proof | E: Explosion proof |
FS-110□: Local indication | IP54 equivalent | - |
FS-115□: Local indication +Alarm contact | IP54 equivalent | d2G4 |
FS-313□: Local indication +Pneumatic output | IP54 equivalent | - |
FS-512□: Local indication +Electric output | IP54 equivalent | Ex d llB T4 |
FS-517□: Local indication +Electric output +Alarm contact | IP54 equivalent | - |
3. Basic Code Selection of FS
Main Code | Suffix Codes | Description | ||||||||||||
FS- | Always FS- | |||||||||||||
Function | 110 | Local indication | ||||||||||||
115 | +Alarm contact (a) | |||||||||||||
313 | +Pneumatic output | |||||||||||||
512 | +Electric output | |||||||||||||
517 | Electric + contact (s) | |||||||||||||
Construction | W- | Weather proof | ||||||||||||
E- | Flameproof | |||||||||||||
S- | Intrinsically safe | |||||||||||||
Chamber construction | 1- | Without chamber | ||||||||||||
2- | Welding type internal chamber | |||||||||||||
3- | Bolt-on internal chamber | |||||||||||||
4- | Insertion type internal chamber | |||||||||||||
5- | Side-side external chamber | |||||||||||||
6- | Side-bottom external chamber | |||||||||||||
9- | Special design | |||||||||||||
Spring | 6 | SUS316 | ||||||||||||
C | UNS N10276 | |||||||||||||
E | Inconel | |||||||||||||
9 | Others | |||||||||||||
Displacer | 4 | SUS304 | ||||||||||||
6 | SUS316 | |||||||||||||
L | SUS316L | |||||||||||||
9 | Others | |||||||||||||
Upper flange | S | Carbon steel | ||||||||||||
4 | SUS304 | |||||||||||||
6 | SUS316 | |||||||||||||
L | SUS316L | |||||||||||||
9 | Others | |||||||||||||
Chamber | S- | Carbon steel | ||||||||||||
4- | SUS304 | |||||||||||||
6- | SUS316 | |||||||||||||
L- | SUS316L | |||||||||||||
9- | Others | |||||||||||||
1- | Without chamber | |||||||||||||
Function | 1 | Liquid level | ||||||||||||
2 | Interface | |||||||||||||
Process flange Size | 3 | 3” flange | ||||||||||||
4 | 4” flange | |||||||||||||
5 | 5” flange | |||||||||||||
6 | 1-1/2” flange | |||||||||||||
9 | Others | |||||||||||||
Process flange rating | 1- | JIS 10K | ||||||||||||
2- | JIS 20K | |||||||||||||
3- | ANSI#150 | |||||||||||||
4- | ANSI#300 | |||||||||||||
5- | JPI#150 | |||||||||||||
6- | JPI#300 | |||||||||||||
9- | Others | |||||||||||||
Output signal | 0 | Nil | ||||||||||||
1 | 1 point | |||||||||||||
2 | 2 points | |||||||||||||
3 | 3 points | |||||||||||||
4 | 4 points | |||||||||||||
5 | 5 points | |||||||||||||
6 | 6 points | |||||||||||||
7 | 20 to 100 kpa=0 to 100% | |||||||||||||
8 | 0.2 to 1.0 bar G=0 to 100% | |||||||||||||
A | 4 to 20 mA DC=0 to100% | |||||||||||||
Z | Others | |||||||||||||
Entry | 1- | Rc(=PT) | ||||||||||||
2- | NPT | |||||||||||||
3- | G(=PF) | |||||||||||||
4- | NPT | |||||||||||||
9- | Others | |||||||||||||
Measuring range | 1- | 300mm | ||||||||||||
2- | 500mm | |||||||||||||
3- | 800mm | |||||||||||||
4- | 1000mm | |||||||||||||
5- | 1200mm | |||||||||||||
6- | 1500mm | |||||||||||||
7- | 1800mm | |||||||||||||
8- | 2000mm | |||||||||||||
9- | 2500mm | |||||||||||||
A- | 3000mm | |||||||||||||
Z- | Order made |
4. Standard Dimensions of FS
Address: P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates