1. General Introduction
System 800xA offers flexible and modular I/O solutions through field bus technologies, wireless I/O and hardwired I/O systems like S800 and S900. The system is now enhanced with S800 on Ethernet and Select I/O. Select I/O allows connecting each signal coming from the field individually. Select I/O is Ethernet connected and consist of single channel granular Signal Conditioning Modules (SCM).
TC810 is a Ethernet Adapter for copper media with built in 2-port switch. Hosts two RJ45 ports. For redundant configuration two Field bus Communication Interfaces CI845, two Ethernet Adapters TC810 and one TU860 or one TU865 are needed.
2. Specification of TC810
General info | |
Type | Ethernet Adapter for copper media |
Article number | 3BSE076220R1 |
Master or slave | Slave |
Line redundancy | Yes |
Module redundancy | Yes |
Hot Swap | Yes |
Detailed data | |
Power dissipation | 1W |
Installation in Hazardous Locations | ATEX – II 3G Ex nA/eC llC T4 Gc Class I, Zone 2, llC T4 Class I, Div 2, Groups A, B, C, D T4 |
Environmental and certification | |
Temperature, Operating | -40°C (-40°F) to +70°C (158°F) |
Temperature, Storage | -40°C (-40°F) to +85°C (185°F) |
Pollution degree | Pollution Degree 2 acc. to IEC 60664-1 |
Relative humidity | 5 to 95 % no condensation |
Altitude | -1000 to 3000 m, (-100 ... 2000 m for Zone 2/Class I Div 2) |
Protection class | IP20 according to EN60529, IEC 529 |
CE- marking | Yes |
Electrical Safety | IEC/EN 61010-1, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No. 61010-2-201 |
Hazardous Area | EN 60079-0, EN60079-7, EN60079-15, UL 12.12.01 / CSA C22.2 No. 213-17 |
Corrosive atmosphere | G3 (ISA-S71.04) |
Marine certificates | ABS, BV, DNV-GL, LR, RS, CCS |
RoHS compliance | DIRECTIVE/2011/65/EU (EN 50581:2012) |
WEEE compliance | DIRECTIVE/2012/19/EU |
Dimensions | |
Width | 110 mm (4.33 in.) |
Depth | 76.3 mm (3.0 in.) |
Height | 24.5 mm (096 in.) |
Weight (including base) | 105 g (0.23 lbs) |
3. Selection table of S800I/O Communication Modules
Name | Line redundancy | Master or slave | Module redundancy | Protocol |
CI801 | No | Slave | No | PROFIBUS DP-V1 |
CI840A | Yes | Slave | Yes | PROFIBUS DP-V1 |
CI845 | Yes | Slave | Yes | N/A |
TB820V2 | No | Slave | No | ABB's Module bus |
TB825(Multi Mode) | No | Slave | No | ABB's Module bus |
TB826(Single Mode) | No | Slave | No | ABB's Module bus |
TB840 | Yes | Slave | Yes | ABB's Module bus |
TB842 | Yes | Slave | Yes | ABB's Module bus |
TC810 | Yes | - | Yes | N/A |
TU807 | - | Not Applicable | - | ABB's Module bus |
TU840 | Yes | Not Applicable | Yes | ABB's Module bus |
TU841 | Yes | Not Applicable | ABB's Module bus | |
TU846 | Yes | Not Applicable | Yes | PROFIBUS DP-V1 |
TU847 | Not Applicable | Yes | PROFIBUS DP-V1 | |
TU848 | Yes | Not Applicable | Yes | ABB's Module bus |
TU849 | Yes | Not Applicable | - | ABB's Module bus |
TU860 | - | - | - | N/A |
Address: P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates